Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Oncol ; 12: 974728, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36106121

RESUMO

Purpose: Carbon-ion beam (C-beam) has a sharp dose distribution called the Bragg peak. Carbon-ion radiation therapy, such as stereotactic body radiotherapy in photon radiotherapy, can be completed in a short period by concentrating the radiation dose on the tumor while minimizing the dose to organs at-risk. However, the stopping position of C-beam is sensitive to density variations along the beam path and such variations can lower the tumor dose as well as cause the delivery of an unexpectedly high dose to the organs at risk. We evaluated the clinical efficacy of a robust planning technique considering gastrointestinal gas (G-gas) to deliver accurate radiation doses in carbon-ion radiotherapy for pancreatic cancer. Materials and methods: We focused on the computed tomography (CT) value replacement method. Replacement signifies the overwriting of CT values in the CT images. The most effective replacement method for robust treatment planning was determined by verifying the effects of the three replacement patterns. We selected 10 consecutive patients. Pattern 1 replaces the CT value of the G-gas contours with the value of the region without G-gas (P1). This condition indicates a no-gas state. Pattern 2 replaces each gastrointestinal contour using the mean CT value of each contour (P2). The effect of G-gas was included in the replacement value. Pattern 3 indicates no replacement (P3). We analyzed variations in the target coverage (TC) and homogeneity index (HI) from the initial plan using in-room CT images. We then performed correlation analysis on the variations in G-gas, TC, and HI to evaluate the robustness against G-gas. Results: Analysis of variations in TC and HI revealed a significant difference between P1 and P3 and between P2 and P3. Although no statistically significant difference was observed between P1 and P2, variations, including the median, tended to be fewer in P2. The correlation analyses for G-gas, TC, and HI showed that P2 was less likely to be affected by G-gas. Conclusion: For a treatment plan that is robust to G-gas, P2 mean replacement method should be used. This method does not necessitate any particular software or equipment, and is convenient to implement in clinical practice.

2.
Case Rep Oncol ; 15(3): 894-901, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36825095

RESUMO

Carbon-ion radiotherapy (CIRT) for prostate cancer is both safe and efficacious; beam range calculations use relative stopping power ratio, which is derived from computed tomography (CT) values. However, hip prostheses are made of high atomic number materials and show severe artifacts on CT images. Therefore, it is not possible to accurately calculate dose distribution for CIRT in patients with prostate cancer with hip prostheses. Here, we describe the management of a 77-year-old man with prostate cancer who had previously undergone bilateral hip replacement. CIRT, in combination with androgen deprivation therapy, was recommended as definitive treatment for prostate cancer. Planning CT, magnetic resonance (MRI), and CT images with metal artifact reduction (MAR) were acquired for CIRT planning. MRI and MAR images were superimposed on the planning CT to delineate target volume and organs at risk. The radiation treatment plan consisted of a total dose of 51.6 Gy (relative biological effect) to be delivered in 12 fractions over 3 weeks, and the patient was irradiated in the supine and prone positions with a vertical beam, on alternating days. CIRT was completed as scheduled. No adverse events were observed during treatment or at 3 months after treatment initiation. While we show that CIRT may be a treatment option for patients with prostate cancer with bilateral hip prostheses, further studies are needed to evaluate treatment efficacy and late toxicity and to determine how CIRT can be administered to patients with prostate cancer with bilateral hip prostheses.

3.
J Appl Clin Med Phys ; 22(6): 130-138, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34046997

RESUMO

PURPOSE: We analyzed interfractional robustness of scanning carbon ion radiotherapy (CIRT) for prostate cancer based on the dose distribution using daily in-room computed tomography (CT) images. MATERIALS AND METHODS: We analyzed 11 consecutive patients treated with scanning CIRT for localized prostate cancer in our hospital between December 2015 and January 2016. In-room CT images were taken under treatment conditions in every treatment session. The dose distribution on each in-room CT image was recalculated, while retaining the pencil beam arrangement of the initial treatment plan. Then, the dose-volume histogram (DVH) parameters including the percentage of the clinical target volume (CTV) with 95% and 90% of the prescribed dose area (V95% of CTV, V90% of CTV) and V80% of rectum were calculated. The acceptance criteria for the CTV and rectum were set at V95% of CTV ≥95%, V90% of CTV ≥98%, and V80% of rectum < 10 ml. RESULTS: V95% of CTV, V90% of CTV, and V80% of rectum for the reproduced plans were 98.8 ± 3.49%, 99.5 ± 2.15%, and 4.39 ± 3.96 ml, respectively. Acceptance of V95% of CTV, V90% of CTV, and V80% of rectum was obtained in 123 (94%), 125 (95%) and 117 sessions (89%), respectively. Acceptance of the mean dose of V95% of CTV, V90% of CTV, and V80% of rectum for each patient was obtained in 10 (91%), 10 (91%), and 11 patients (100%), respectively. CONCLUSIONS: We demonstrated acceptable interfractional robustness based on the dose distribution in scanning CIRT for prostate cancer.


Assuntos
Radioterapia com Íons Pesados , Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Reto/diagnóstico por imagem , Tomografia Computadorizada por Raios X
4.
In Vivo ; 35(1): 447-452, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33402495

RESUMO

BACKGROUND/AIM: The present study aimed to compare the radiation dose distribution of carbon-ion radiotherapy (CIRT) for stage I esophageal cancer with three-dimensional conformal radiotherapy (3DCRT) and volumetric modulated arc therapy (VMAT). PATIENTS AND METHODS: Fifteen patients with cT1bN0M0 esophageal cancer who received 3DCRT at Kanagawa Cancer Center between January 2014 and April 2019 were enrolled. The dose-volume histogram parameters of the target volume and normal organs planned with CIRT, 3DCRT, and VMAT were evaluated. RESULTS: The homogeneity index for the target volume of CIRT was significantly lower than that of 3DCRT and VMAT. In addition, the radiation dose of CIRT to the heart, lungs, spinal cord, and skin was significantly lower than that of 3DCRT and VMAT. CONCLUSION: Favorable dose distributions with CIRT were demonstrated compared with 3DCRT and VMAT for esophageal cancer.


Assuntos
Neoplasias Esofágicas , Radioterapia de Intensidade Modulada , Carbono , Neoplasias Esofágicas/radioterapia , Humanos , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...